Add the following code to your mqtt.yaml file:
sensor:
# Grid meter power
- state_topic: "venus-home/N/c0619xxxxxx/grid/30/Ac/Power"
name: "Grid power"
unique_id: "grid_meter_power"
device_class: power
value_template: '{{ value_json.value | round(0) }}'
unit_of_measurement: "W"
icon: mdi:TransmissionTower
# Victron alarms
- state_topic: "venus-home/N/c0619xxxxxx/battery/512/Alarms/CellImbalance"
name: "Alarm cell imbalance"
unique_id: "alarm_battery_cell_imbalance"
value_template: >
{% if value_json.value == 0 %}
OK
{% elif value_json.value == 1 %}
Warning
{% elif value_json.value == 2 %}
Alarm
{% endif %}
- state_topic: "venus-home/N/c0619xxxxxx/battery/512/Alarms/ChargeBlocked"
name: "Alarm Charge blocked"
unique_id: "alarm_battery_charge_blocked"
value_template: >
{% if value_json.value == 0 %}
OK
{% elif value_json.value == 1 %}
Warning
{% elif value_json.value == 2 %}
Alarm
{% endif %}
- state_topic: "venus-home/N/c0619xxxxxx/battery/512/Alarms/DischargeBlocked"
name: "Alarm Discharge blocked"
unique_id: "alarm_battery_discharge_blocked"
value_template: >
{% if value_json.value == 0 %}
OK
{% elif value_json.value == 1 %}
Warning
{% elif value_json.value == 2 %}
Alarm
{% endif %}
- state_topic: "venus-home/N/c0619xxxxxx/battery/512/Alarms/HighChargeCurrent"
name: "Alarm high charge current"
unique_id: "alarm_battery_high_charge_current"
value_template: >
{% if value_json.value == 0 %}
OK
{% elif value_json.value == 1 %}
Warning
{% elif value_json.value == 2 %}
Alarm
{% endif %}
- state_topic: "venus-home/N/c0619xxxxxx/battery/512/Alarms/HighChargeTemperature"
name: "Alarm high charge temperature"
unique_id: "alarm_battery_high_charge_temperature"
value_template: >
{% if value_json.value == 0 %}
OK
{% elif value_json.value == 1 %}
Warning
{% elif value_json.value == 2 %}
Alarm
{% endif %}
- state_topic: "venus-home/N/c0619xxxxxx/battery/512/Alarms/HighDischargeCurrent"
name: "Alarm high discharge current"
unique_id: "alarm_battery_high_discharge_current"
value_template: >
{% if value_json.value == 0 %}
OK
{% elif value_json.value == 1 %}
Warning
{% elif value_json.value == 2 %}
Alarm
{% endif %}
- state_topic: "venus-home/N/c0619xxxxxx/battery/512/Alarms/HighTemperature"
name: "Alarm high temperature"
unique_id: "alarm_battery_high_temperature"
value_template: >
{% if value_json.value == 0 %}
OK
{% elif value_json.value == 1 %}
Warning
{% elif value_json.value == 2 %}
Alarm
{% endif %}
- state_topic: "venus-home/N/c0619xxxxxx/battery/512/Alarms/HighVoltage"
name: "Alarm high voltage"
unique_id: "alarm_battery_high_voltage"
value_template: >
{% if value_json.value == 0 %}
OK
{% elif value_json.value == 1 %}
Warning
{% elif value_json.value == 2 %}
Alarm
{% endif %}
- state_topic: "venus-home/N/c0619xxxxxx/battery/512/Alarms/InternalFailure"
name: "Alarm internal failure"
unique_id: "alarm_battery_internal_failure"
value_template: >
{% if value_json.value == 0 %}
OK
{% elif value_json.value == 1 %}
Warning
{% elif value_json.value == 2 %}
Alarm
{% endif %}
- state_topic: "venus-home/N/c0619xxxxxx/battery/512/Alarms/LowChargeTemperature"
name: "Alarm low charge temperature"
unique_id: "alarm_battery_low_charge_temp"
value_template: >
{% if value_json.value == 0 %}
OK
{% elif value_json.value == 1 %}
Warning
{% elif value_json.value == 2 %}
Alarm
{% endif %}
- state_topic: "venus-home/N/c0619xxxxxx/battery/512/Alarms/LowTemperature"
name: "Alarm low temperature"
unique_id: "alarm_battery_low_temp"
value_template: >
{% if value_json.value == 0 %}
OK
{% elif value_json.value == 1 %}
Warning
{% elif value_json.value == 2 %}
Alarm
{% endif %}
- state_topic: "venus-home/N/c0619xxxxxx/battery/512/Alarms/LowVoltage"
name: "Alarm low voltage"
unique_id: "alarm_battery_low_voltage"
value_template: >
{% if value_json.value == 0 %}
OK
{% elif value_json.value == 1 %}
Warning
{% elif value_json.value == 2 %}
Alarm
{% endif %}
# Victron Cerbo GX Serial number
- state_topic: "venus-home/N/c0619xxxxxx/system/0/Serial"
name: "Cerbo GX Serial number"
unique_id: "victron_cerbo_serial"
value_template: '{{ value_json.value }}'
# Active SoC limit
- state_topic: "venus-home/N/c0619xxxxxx/system/0/Control/ActiveSocLimit"
name: "Active SoC limit"
unique_id: "active_soc_limit"
device_class: battery
unit_of_measurement: "%"
value_template: '{{ value_json.value | round(0)}}'
icon: mdi:battery-low
# AC ActiveIN L1 Current
- state_topic: "venus-home/N/c0619xxxxxx/system/0/Ac/ActiveIn/L1/Current"
name: "AC ActiveIn L1 Current"
unique_id: "victron_activein_L1_current"
device_class: current
value_template: '{{ value_json.value |float(0)|round(2) }}'
unit_of_measurement: "A"
icon: mdi:power-socket-eu
# AC ActiveIN L1 Current
- state_topic: "venus-home/N/c0619xxxxxx/system/0/Ac/ActiveIn/L2/Current"
name: "AC ActiveIn L2 Current"
unique_id: "victron_activein_L2_current"
device_class: current
value_template: '{{ value_json.value |float(0)|round(2) }}'
unit_of_measurement: "A"
icon: mdi:power-socket-eu
# AC ActiveIN L1 Current
- state_topic: "venus-home/N/c0619xxxxxx/system/0/Ac/ActiveIn/L3/Current"
name: "AC ActiveIn L3 Current"
unique_id: "victron_activein_L3_current"
device_class: current
value_template: '{{ value_json.value |float(0)|round(2) }}'
unit_of_measurement: "A"
icon: mdi:power-socket-eu
# Grid Lost Status
- state_topic: "venus-home/N/c0619xxxxxx/vebus/276/Alarms/GridLost"
name: "Grid Lost Status"
unique_id: "victron_grid_lost_status"
value_template: >
{% if value_json.value == 0 %}
Grid Connected
{% elif value_json.value == 2 %}
Grid Lost
{% endif %}
# Current Grid Setpoint
- state_topic: "venus-home/N/c0619xxxxxx/settings/0/Settings/CGwacs/AcPowerSetPoint"
name: "Current grid setpoint"
unique_id: "current_grid_setpoint"
device_class: power
value_template: '{{ value_json.value }}'
unit_of_measurement: "W"
# Battery percentage
- state_topic: "venus-home/N/c0619xxxxxx/battery/512/Soc"
name: "Battery Percent"
unique_id: "battery_percent"
device_class: battery
value_template: '{{ value_json.value | round(1) }}'
unit_of_measurement: "%"
# Battery percentage
- state_topic: "venus-home/N/c0619xxxxxx/battery/512/Soh"
name: "Battery Health"
unique_id: "battery_health"
device_class: battery
value_template: '{{ value_json.value | round(1) }}'
unit_of_measurement: "%"
# AC Loads
- state_topic: "venus-home/N/c0619xxxxxx/vebus/276/Ac/Out/P"
name: "AC Loads"
unique_id: "ac_loads"
device_class: power
value_template: '{{ value_json.value }}'
unit_of_measurement: "W"
icon: mdi:power-socket-eu
# L1 Load
- state_topic: "venus-home/N/c0619xxxxxx/vebus/276/Ac/Out/L1/P"
name: "L1 Load"
unique_id: "L1_load"
device_class: power
value_template: '{{ value_json.value }}'
unit_of_measurement: "W"
icon: mdi:power-socket-eu
# L1 Output Voltage
- state_topic: "venus-home/N/c0619xxxxxx/vebus/276/Ac/Out/L1/V"
name: "L1 Output Voltage"
unique_id: "L1_Output_Voltage"
device_class: voltage
value_template: '{{ value_json.value|round(1) }}'
unit_of_measurement: "V"
icon: mdi:power-socket-eu
# L1 Output frequency
- state_topic: "venus-home/N/c0619xxxxxx/vebus/276/Ac/Out/L1/F"
name: "L1 output frequency"
unique_id: "L1_output_frequency"
device_class: frequency
value_template: '{{ value_json.value|round(1) }}'
unit_of_measurement: "Hz"
icon: mdi:sine-wave
# L2 Load
- state_topic: "venus-home/N/c0619xxxxxx/vebus/276/Ac/Out/L2/P"
name: "L2 Load"
unique_id: "L2_load"
device_class: power
value_template: '{{ value_json.value }}'
unit_of_measurement: "W"
icon: mdi:power-socket-eu
# L2 Output Voltage
- state_topic: "venus-home/N/c0619xxxxxx/vebus/276/Ac/Out/L2/V"
name: "L2 Output Voltage"
unique_id: "L2_Output_Voltage"
device_class: voltage
value_template: '{{ value_json.value|round(1) }}'
unit_of_measurement: "V"
icon: mdi:power-socket-eu
# L2 Output frequency
- state_topic: "venus-home/N/c0619xxxxxx/vebus/276/Ac/Out/L2/F"
name: "L2 output frequency"
unique_id: "L2_output_frequency"
device_class: frequency
value_template: '{{ value_json.value|round(1) }}'
unit_of_measurement: "Hz"
icon: mdi:sine-wave
# L3 Load
- state_topic: "venus-home/N/c0619xxxxxx/vebus/276/Ac/Out/L3/P"
name: "L3 Load"
unique_id: "L3_load"
device_class: power
value_template: '{{ value_json.value }}'
unit_of_measurement: "W"
icon: mdi:power-socket-eu
# L3 Output Voltage
- state_topic: "venus-home/N/c0619xxxxxx/vebus/276/Ac/Out/L3/V"
name: "L3 Output Voltage"
unique_id: "L3_Output_Voltage"
device_class: voltage
value_template: '{{ value_json.value|round(1) }}'
unit_of_measurement: "V"
icon: mdi:power-socket-eu
# L3 Output frequency
- state_topic: "venus-home/N/c0619xxxxxx/vebus/276/Ac/Out/L3/F"
name: "L3 output frequency"
unique_id: "L3_output_frequency"
device_class: frequency
value_template: '{{ value_json.value|round(1) }}'
unit_of_measurement: "Hz"
icon: mdi:sine-wave
# L1 Grid
- state_topic: "venus-home/N/c0619xxxxxx/system/0/Ac/Grid/L1/Power"
name: "L1 Grid"
unique_id: "L1_grid"
device_class: power
value_template: '{{ value_json.value }}'
unit_of_measurement: "W"
icon: mdi:power-socket-eu
# L2 Grid
- state_topic: "venus-home/N/c0619xxxxxx/system/0/Ac/Grid/L2/Power"
name: "L2 Grid"
unique_id: "L2_grid"
device_class: power
value_template: '{{ value_json.value }}'
unit_of_measurement: "W"
icon: mdi:power-socket-eu
# L3 Grid
- state_topic: "venus-home/N/c0619xxxxxx/system/0/Ac/Grid/L3/Power"
name: "L3 Grid"
unique_id: "L3_grid"
device_class: power
value_template: '{{ value_json.value }}'
unit_of_measurement: "W"
icon: mdi:power-socket-eu
# DC Loads
- name: "DC Loads"
device_class: power
unique_id: "dc_loads"
state_topic: "venus-home/N/c0619xxxxxx/system/0/Dc/System/Power"
value_template: '{{ value_json.value|float(0)|round(0) }}'
unit_of_measurement: "W"
icon: mdi:power
# Net Solar Production
- name: "Current Solar Production"
unique_id: "net_solar_production"
device_class: power
state_topic: "venus-home/N/c0619xxxxxx/system/0/Dc/Pv/Power"
value_template: '{{ value_json.value|float(0)|round(0) }}'
unit_of_measurement: "W"
icon: mdi:solar-power
# Battery Voltage
- name: "Battery Voltage"
unique_id: "battery_voltage"
device_class: voltage
state_topic: "venus-home/N/c0619xxxxxx/system/0/Dc/Battery/Voltage"
value_template: '{{ value_json.value|float(0)|round(1) }}'
unit_of_measurement: "V"
# Battery Temp (If you have a temp sensor)
- name: "Battery Temp"
device_class: temperature
unique_id: "battery_temperature"
state_topic: "venus-home/N/c0619xxxxxx/system/0/Dc/Battery/Temperature"
value_template: '{{ ((value_json.value * 9/5) + 32) | round(0) }}'
unit_of_measurement: "°F"
# Net load going in/out of your battery
- name: "Battery Load"
unique_id: "battery_load"
device_class: power
state_topic: "venus-home/N/c0619xxxxxx/system/0/Dc/Vebus/Power"
value_template: '{{ value_json.value |float(0)|round(0) }}'
unit_of_measurement: "W"
# Net current going in/out of your battery
- name: "Battery Current"
unique_id: "battery_current"
device_class: current
state_topic: "venus-home/N/c0619xxxxxx/system/0/Dc/Vebus/Current"
value_template: '{{ value_json.value |float(0)|round(0) }}'
unit_of_measurement: "A"
# Temperature Multiplus II - Phase 1
- name: "Temperature MPII #1"
unique_id: "temp_mpII_1"
device_class: temperature
state_topic: "venus-home/N/c0619xxxxxx/temperature/25/Temperature"
value_template: '{{ value_json.value |float(0)|round(0) }}'
unit_of_measurement: "°C"
# Temperature Multiplus II - Phase 2
- name: "Temperature MPII #2"
unique_id: "temp_mpII_2"
device_class: temperature
state_topic: "venus-home/N/c0619xxxxxx/temperature/26/Temperature"
value_template: '{{ value_json.value |float(0)|round(0) }}'
unit_of_measurement: "°C"
# Temperature Multiplus II - Phase 3
- name: "Temperature MPII #3"
unique_id: "temp_mpII_3"
device_class: temperature
state_topic: "venus-home/N/c0619xxxxxx/temperature/27/Temperature"
value_template: '{{ value_json.value |float(0)|round(0) }}'
unit_of_measurement: "°C"
# Temperature Multiplus II - Phase 3
- name: "Pylontech battery power"
unique_id: "pylontech_batt_power"
device_class: power
state_topic: "venus-home/N/c0619xxxxxx/battery/512/Dc/0/Power"
value_template: '{{ value_json.value |round(0) }}'
unit_of_measurement: "W"
# Current State of your Inverter
- name: "Inverter State"
unique_id: "inverter_state"
state_topic: "venus-home/N/c0619xxxxxx/system/0/SystemState/State"
value_template: >
{% if value_json.value == 0 %}
Off
{% elif value_json.value == 1 %}
Low power
{% elif value_json.value == 2 %}
VE.Bus Fault condition
{% elif value_json.value == 3 %}
Bulk charging
{% elif value_json.value == 4 %}
Absorption charging
{% elif value_json.value == 5 %}
Float charging
{% elif value_json.value == 6 %}
Storage mode
{% elif value_json.value == 7 %}
Equalize
{% elif value_json.value == 8 %}
Passthru
{% elif value_json.value == 9 %}
Inverting
{% elif value_json.value == 10 %}
Assisting
{% elif value_json.value == 252 %}
External control
{% elif value_json.value == 256 %}
Discharging
{% elif value_json.value == 257 %}
Sustain
{% elif value_json.value == 258 %}
Recharging
{% elif value_json.value == 259 %}
Scheduled recharging
{% else %}
Error - No Data
{% endif %}
# Current state of your charge controller
- name: "Solar Charger State"
unique_id: "solar_charger_state"
state_topic: "venus-home/N/c0619xxxxxx/solarcharger/289/State"
value_template: >
{% if value_json.value == 0 %}
Off
{% elif value_json.value == 2 %}
Fault
{% elif value_json.value == 3 %}
Bulk
{% elif value_json.value == 4 %}
Absorption
{% elif value_json.value == 5 %}
Float
{% elif value_json.value == 6 %}
Storage
{% elif value_json.value == 7 %}
Equalize
{% else %}
Error - No Data
{% endif %}
switch:
#Multiplus Entladeleistung Begrenzen !Number
- unique_id: multiplus_switch_discharge_power
name: Inverter Power
command_topic: "venus-home/W/c0619xxxxxx/settings/0/Settings/CGwacs/MaxDischargePower"
payload_on: '{"value": 1000}'
payload_off: '{"value": -1}'
state_topic: "venus-home/N/c0619xxxxxx/settings/0/Settings/CGwacs/MaxDischargePower"
value_template: >
{% if value_json.value | int == -1 %}
{% set state_limit = 'OFF' %}
{% else %}
{% set state_limit = 'ON' %}
{% endif %}
{{ state_limit }}
state_on: 'ON'
state_off: 'OFF'
device: {
identifiers: [
"Victron Cerbo GX"
],
manufacturer: "Victron Energy",
model: "Cerbo GX",
name: "Cerbo GX"}
#Multiplus AC PV-Überschuss einspeisen
- unique_id: multiplus_allow_ac_feed_in
name: Multiplus allow AC feed in
command_topic: "venus-home/W/c0619xxxxxx/settings/0/Settings/CGwacs/PreventFeedback"
payload_on: '{"value": 0}'
payload_off: '{"value": 1}'
state_topic: "venus-home/N/c0619xxxxxx/settings/0/Settings/CGwacs/PreventFeedback"
value_template: "{{ value_json.value | int }}"
state_on: '0'
state_off: '1'
device: {
identifiers: [
"Victron Cerbo GX"
],
manufacturer: "Victron Energy",
model: "Cerbo GX",
name: "Cerbo GX"}
#Multiplus DC PV-Überschuss einspeisen
- unique_id: multiplus_allow_dc_feed_in
name: Multiplus allow DC feed in
command_topic: "venus-home/W/c0619xxxxxx/settings/0/Settings/CGwacs/OvervoltageFeedIn"
payload_on: '{"value": 1}'
payload_off: '{"value": 0}'
state_topic: "venus-home/N/c0619xxxxxx/settings/0/Settings/CGwacs/OvervoltageFeedIn"
value_template: "{{ value_json.value | int }}"
state_on: '1'
state_off: '0'
device: {
identifiers: [
"Victron Cerbo GX"
],
manufacturer: "Victron Energy",
model: "Cerbo GX",
name: "Cerbo GX"}